SUNverter | SUNverter Price in India | 1000VA Sunverter
Ready to Replace Conventional Inverters by its 50 amp Solar Charge Controller & built in
Sun Clock Approximation (SCA) Technology.












  • True hybrid solar PCU with 50amp. in built PWM solar charge controller.
  • Excellent Charging at low Mains voltage.
  • New Generation MOSFET based PWM technology with greater efficiency at lower cost Dynamic Stability.
  • User friendly graphic led panel Display defining working parameter of Power source for load.
  • Smart battery selection option with indicator.
  • Selector switch of ups/inv.& high/ low charging on the front bezel for ease of operation.
  • Enhanced Temperature Protection.
  • Complete protection of short circuit, phase reversal & overload.
  • Supports fully deep discharge batteries.
  • Internally selects solar distribution as per the load hence saves power & money by use SCA (Sun Clock Approximation).

NB.The technical specifications and perameters are only for quick reference. For installation and product purchase, kindly take technical expert guidance.


  • Nominal Battery Voltage: 24VDC
  • Input Voltage Range (Normal Mode): 100 to 290 VAC+_ 10 VAC
  • Input Voltage Range (UPS Mode): 180 to 265 VAC+_ 10 VAC
  • Battery Selection Tubular, Flat, SMF/Loc.
  • Protections : Over Load, Short Circuit, PV Reverse Polarity Protection.
  • Solar Charge Controller Logic based on SUN Clock Approximation

NB.The technical specifications and perameters are only for quick reference. For installation and product purchase, kindly take technical expert guidance.


BATTERY MODE 2000VA/24V
No Load Current @ Switch OFF ≤50mA
No Load Current @ Switch ON ≤1.8Amp
Output Voltage @ No LOAD 230V Nominal
Full LOAD Output Voltage @ 24VDC 210 ± 5 Volt.
Battery Current @ Full LOAD 62 ± 1 Amp.
Thermal Management Temperature Control by Fan
UPS MODE
Low Cut With Phase Match 180 ± 10V
Low Cut Recovery With Phase Match 9-12V Hysterisis from > Low Cut Voltage
High Cut With Phase Match 265 ± 10V
High Cut Reovery With Phase Match 9-12V Hysterisis from < High Cut Voltage
Change Over Time From Mains To UPS ≤ 10msec
Change Over Time From UPS To Mains ≤ 10msec
NORMAL MODE
Low Cut With Phase Match 100 ± 10V
Low Cut Recovery With Phase Match 9-12V Hysterisis > Low Cut Voltage
High Cut With Phase Match 290 ± 10V
High Cut Reovery With Phase Match 9-12V Hysterisis < High Cut Voltage
Change Over Time From Mains To UPS ≤ 40msec
Change Over Time From UPS To Mains ≤ 10msec
CHARGING MODE
Low Charging Current @ 220V AC (NC) 12.0 ± 1.0 Amp.
High Charging Current @ 220V AC (HC) 16.0 ± 1.0 Amp.
Battery Boost Voltage as per Table ‘A’
Float Voltage 27.2 ± 0.4 Volt.

NB.The technical specifications and perameters are only for quick reference. For installation and product purchase, kindly take technical expert guidance.





  • True hybrid solar PCU with 50amp. in built PWM solar charge controller.
  • Excellent Charging at low Mains voltage.
  • New Generation MOSFET based PWM technology with greater efficiency at lower cost Dynamic Stability.
  • User friendly graphic led panel Display defining working parameter of Power source for load.
  • Smart battery selection option with indicator.
  • Selector switch of ups/inv.& high/ low charging on the front bezel for ease of operation.
  • Enhanced Temperature Protection.
  • Complete protection of short circuit, phase reversal & overload.
  • Supports fully deep discharge batteries.
  • Internally selects solar distribution as per the load hence saves power & money by use SCA (Sun Clock Approximation).

  • Nominal Battery Voltage: 12VDC
  • Input Voltage Range (Normal Mode): 100 to 290 VAC+_ 10 VAC
  • Input Voltage Range (UPS Mode): 180 to 265 VAC+_ 10 VAC
  • Battery Selection Tubular, Flat, SMF/Loc.
  • Protections :Over Load, Short Circuit, PV Reverse Polarity Protection.
  • Solar Charge Controller Logic based on SUN Clock Approximation

BATTERY MODE 1000VA/12V
No Load Current @ Switch OFF ≤50mA
No Load Current @ Switch ON ≤2.2Amp
Output Voltage @ No LOAD 230V Nominal
Full LOAD Output Voltage @ 24VDC 200 ± 5 Volt.
Battery Current @ Full LOAD 62 ± 1 Amp.
Thermal Management Temperature Control by Fan
UPS MODE
Low Cut With Phase Match 180 ± 10V
Low Cut Recovery With Phase Match 9-12V Hysterisis from > Low Cut Voltage
High Cut With Phase Match 265 ± 10V
High Cut Reovery With Phase Match 9-12V Hysterisis from < High Cut Voltage
Change Over Time From Mains To UPS ≤ 10msec
Change Over Time From UPS To Mains ≤ 10msec
NORMAL MODE
Low Cut With Phase Match 100 ± 10V
Low Cut Recovery With Phase Match 9-12V Hysterisis > Low Cut Voltage
High Cut With Phase Match 290 ± 10V
High Cut Reovery With Phase Match 9-12V Hysterisis < High Cut Voltage
Change Over Time From Mains To UPS ≤ 40msec
Change Over Time From UPS To Mains ≤ 10msec
CHARGING MODE
Low Charging Current @ 220V AC (NC) 12.0 ± 1.0 Amp.
High Charging Current @ 220V AC (HC) 16.0 ± 1.0 Amp.
Battery Boost Voltage as per Table ‘A’
Float Voltage 13.6 ± 0.2 Volt.